Products
YG606D flat plate heat preservation instrument

Scope of application

This instrument mainly uses human body temperature (36) as the standard to measure the thermal insulation performance of ordinary fabrics, knitted fabrics, raised fabrics, quilted product cushions and various thermal insulation materials. It adopts microcomputer control, large-screen LCD display, automatic data processing, and printout, easy to set up procedures, accurate, fast and convenient testing, it is a necessary universal instrument for correct evaluation of fabric warmth performance indicators.

Related standards

GB/T11048, ASTMD1518, JIS-1096, etc.

technical parameter

1. The temperature adjustment range of the heating plate: 2050

2. Preheating time setting range: 099 minutes

3. Circulating heating cycle setting range: 19 times

4. Test times: 1-9 times

5. Small resolution of temperature display value: 0.1

6. The technical parameters of the heating plate: test plate 40W, protection plate 80W, bottom plate 120W

7. Test board size: 250×250 mm

8. Test bench size: 510×51×640 mm

9. Overall dimensions of electrical control box: 300×345×150 mm

10. Power supply: AC 220V±5%, 50Hz

11. Net weight: 30kg